Operated by Cornell University

OBS deployed from May 2018 to Oct 2019

DOI: https://doi.org/10.7914/SN/XO_2018

=> Network Stations

=> Network Station Channels

Network Map

Network Stations

NetworkStationStart TimeEnd TimeLatitudeLongitudeDepthChannels
XOWD512018/07/202019/09/0155.905087-152.771768-4361HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWS742018/07/182019/09/0454.369193-159.361628-902HH1-HH2-HHZ-HN1-HN2-HNZ (100.0 Hz)
BDH (40.0 Hz)
LDH-LDI-LH1-LH2-LHZ-LN1-LN2-LNZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWS752018/07/182019/09/0454.17963-160.256908-1108HH1-HH2-HHZ-HN1-HN2-HNZ (100.0 Hz)
BDH (40.0 Hz)
LDH-LDI-LH1-LH2-LHZ-LN1-LN2-LNZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD502018/07/212019/08/2955.449527-152.391763-4986HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD462018/07/122019/09/1155.521393-149.703732-4349HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD522018/07/182019/09/0354.046622-159.346215-2564HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD532018/07/132019/09/1053.779448-153.422908-4646HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD472018/07/132019/09/1154.951352-150.444792-3999HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWS722018/07/212019/08/2956.257748-151.81063-4141HH1-HH2-HHZ-HN1-HN2-HNZ (100.0 Hz)
BDH (40.0 Hz)
LDH-LDI-LH1-LH2-LHZ-LN1-LN2-LNZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD572018/07/192019/08/3154.736387-154.434305-5053HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD562018/07/192019/08/3055.322267-154.047078-4060HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWS732018/07/182019/10/2254.419958-158.513277-2132HH1-HH2-HHZ-HN1-HN2-HNZ (100.0 Hz)
BDH (40.0 Hz)
LDH-LDI-LH1-LH2-LHZ-LN1-LN2-LNZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD542018/07/222019/09/1156.331433-149.066665-4520HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOLD382018/05/252019/08/2855.1649-151.6756-4043HDH-HH1-HH2-HHZ (100.0 Hz)
XOWS712018/07/202019/09/0356.15695-153.078922-1554HH1-HH2-HHZ-HN1-HN2-HNZ (100.0 Hz)
BDH (40.0 Hz)
LDH-LDI-LH1-LH2-LHZ-LN1-LN2-LNZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD682018/07/172019/09/0652.917603-160.081145-4715HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD692018/07/172019/09/0353.782065-160.34289-3896HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD552018/07/202019/09/0155.761625-153.662817-1284HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOLT092018/05/142019/08/1955.1215-157.1389-151HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT082018/05/132019/08/2855.5883-156.5975-246HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT202018/05/162019/08/2254.8002-161.3746-150HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA392018/05/272019/08/1156.8827-151.0011-1628HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA282018/05/142019/08/2054.8983-156.603-1852HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA292018/05/212019/08/2654.2918-157.3705-4408HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT182018/05/172019/08/2354.74-160.5814-115EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT142018/05/122019/08/1855.6998-158.0302-125HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA332018/05/212019/08/2554.1528-158.1143-4478HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA262018/05/222019/08/2054.5129-156.2561-5103HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA322018/05/152019/08/2154.4982-157.8522-1595HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT152018/05/122019/08/2155.2002-158.3598-167HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT012018/05/242019/08/1456.7756-152.5228-156HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT172018/05/162019/08/2354.5677-160.2016-114EDH-HH1-HH2-HHZ (100.0 Hz)
XOLD402018/05/252019/08/1356.3037-152.4102-1055HDH-HH1-HH2-HHZ (100.0 Hz)
XOLT032018/05/102019/08/1557.8668-154.1665-202HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA302018/05/142019/08/2154.6727-157.4203-1564HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA252018/05/142019/08/2054.8901-155.9408-2622HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT022018/05/242019/08/2856.6932-153.2611-152HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT162018/05/122019/08/2255.4916-158.6013-125HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLD412018/05/232019/08/2754.5219-153.4074-4284HDH-HH1-HH2-HHZ (100.0 Hz)
XOLD452018/05/202019/08/2454.1025-159.8829-2019HDH-HH1-HH2-HHZ (100.0 Hz)
XOLT122018/05/132019/08/1955.207-157.778-83HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT062018/05/122019/08/1756.2167-155.9979-225HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA212018/05/222019/08/2654.3691-155.0735-5113HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA342018/05/202019/08/2554.0449-158.5881-4612HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT072018/05/112019/08/1556.6712-156.1199-262HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLD442018/05/202019/08/2453.8302-159.7736-4675HDH-HH1-HH2-HHZ (100.0 Hz)
XOLT132018/05/152019/08/2254.8439-158.3466-203HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT052018/05/112019/08/1556.823-155.3469-236HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT112018/05/122019/08/2856.1202-157.3355-162HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLA222018/05/232019/08/2755.2576-155.153-2130HDH (125.0 Hz)
EDH (100.0 Hz)
XOLA232018/05/232019/08/2654.9163-155.2376-3977HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT102018/05/132019/08/1855.6251-157.3251-98HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOLT042018/05/242019/08/1456.1118-154.4446-157HDH (125.0 Hz)
EDH-HH1-HH2-HHZ (100.0 Hz)
XOWD582018/07/142019/09/0953.906227-155.035345-4493HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD702018/07/222019/08/2856.541073-151.234407-3253HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD642018/07/162019/09/0952.001077-158.691562-4754HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD652018/07/162019/09/0852.899057-158.91238-4718HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD592018/07/142019/09/1053.383713-155.799387-4550HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOLD352018/05/162019/08/2554.2495-158.872-1993HDH-HH1-HH2-HHZ (100.0 Hz)
XOLD372018/05/252019/08/2855.6764-151.1005-4826HDH-HH1-HH2-HHZ (100.0 Hz)
XOWD672018/07/162019/09/0752.162563-160.035832-4652HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD662018/07/172019/09/0653.31452-159.617565-4941HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOLD362018/05/142019/08/2055.2524-155.7525-935HDH-HH1-HH2-HHZ (100.0 Hz)
XOWD622018/07/152019/09/0853.361962-157.331882-4626HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD632018/07/152019/09/0852.590072-158.093575-4656HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD612018/07/192019/09/0154.647613-156.868282-2067HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD492018/07/132019/09/1154.399083-151.89947-4091HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD482018/07/212019/09/0456.627365-151.731343-1324HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)
XOWD602018/07/142019/09/0752.644867-156.579823-4519HDH-HH1-HH2-HHZ (100.0 Hz)
LDH-LH1-LH2-LHZ (1.0 Hz)
VM0-VM1-VM2-VM3-VM4-VM5-VM6-VMU-VMV-VMW-VMZ-VPB (0.1 Hz)

Network Station Channels

StationChannelsSample RateSensor Description
WS74 WS75 WS72 WS73 WS71BDH40.0SIO Differential Pressure Gauge/QEP - Q330 Environ
LT09 LT08 LT20 LA39 LA28 LA29 LT18 LT14 LA33 LA26 LA32 LT15 LT01 LT17 LT03 LA30 LA25 LT02 LT16 LT12 LT06 LA21 LA34 LT07 LT13 LT05 LT11 LA22 LA23 LT10 LT04EDH100.0LDEO HTI90U/LDEO OBS 2011 logger
LD38 LD40 LD41 LD45 LD44 LD35 LD37 LD36HDH100.0LDEO DPG/LDEO OBS 2011 logger
WD51 WD50 WD46 WD52 WD53 WD47 WD57 WD56 WD54 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60HDH100.0SIO Differential Pressure Gauge/Quanterra Q330 Lin
LT09 LT08 LT20 LA39 LA28 LA29 LT14 LA33 LA26 LA32 LT15 LT01 LT03 LA30 LA25 LT02 LT16 LT12 LT06 LA21 LA34 LT07 LT13 LT05 LT11 LA22 LA23 LT10 LT04HDH125.0Parosci APG Pressure/LDEO_APG_logger
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60HH1100.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
LD38 LT09 LT08 LT20 LA39 LA28 LA29 LT18 LT14 LA33 LA26 LA32 LT15 LT01 LT17 LD40 LT03 LA30 LA25 LT02 LT16 LD41 LD45 LT12 LT06 LA21 LA34 LT07 LD44 LT13 LT05 LT11 LA23 LT10 LT04 LD35 LD37 LD36HH1100.0Nanometrics Trillium Compact Response/LDEO OBS 201
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60HH2100.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
LD38 LT09 LT08 LT20 LA39 LA28 LA29 LT18 LT14 LA33 LA26 LA32 LT15 LT01 LT17 LD40 LT03 LA30 LA25 LT02 LT16 LD41 LD45 LT12 LT06 LA21 LA34 LT07 LD44 LT13 LT05 LT11 LA23 LT10 LT04 LD35 LD37 LD36HH2100.0Nanometrics Trillium Compact Response/LDEO OBS 201
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60HHZ100.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
LD38 LT09 LT08 LT20 LA39 LA28 LA29 LT18 LT14 LA33 LA26 LA32 LT15 LT01 LT17 LD40 LT03 LA30 LA25 LT02 LT16 LD41 LD45 LT12 LT06 LA21 LA34 LT07 LD44 LT13 LT05 LT11 LA23 LT10 LT04 LD35 LD37 LD36HHZ100.0Nanometrics Trillium Compact Response/LDEO OBS 201
WS74 WS75 WS72 WS73 WS71HN1100.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WS74 WS75 WS72 WS73 WS71HN2100.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WS74 WS75 WS72 WS73 WS71HNZ100.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WS74 WS75 WS72 WS73 WS71LDH1.0SIO Differential Pressure Gauge/QEP - Q330 Environ
WD51 WD50 WD46 WD52 WD53 WD47 WD57 WD56 WD54 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60LDH1.0SIO Differential Pressure Gauge/Quanterra Q330 Lin
WS74 WS75 WS72 WS73 WS71LDI1.0QEP - Q330 Environmental Processor
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60LH11.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60LH21.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60LHZ1.0Guralp CMG3T_120sec WHOI OBSIP/Quanterra Q330 Line
WS74 WS75 WS72 WS73 WS71LN11.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WS74 WS75 WS72 WS73 WS71LN21.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WS74 WS75 WS72 WS73 WS71LNZ1.0Episensor 200 Hz 5 Volt per g/Quanterra Q330 Linea
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM00.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM10.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM20.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM30.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM40.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM50.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VM60.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VMU0.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VMV0.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VMW0.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VMZ0.1Quanterra Q330 Linear Phase Composite
WD51 WS74 WS75 WD50 WD46 WD52 WD53 WD47 WS72 WD57 WD56 WS73 WD54 WS71 WD68 WD69 WD55 WD58 WD70 WD64 WD65 WD59 WD67 WD66 WD62 WD63 WD61 WD49 WD48 WD60VPB0.1Quanterra Q330 Linear Phase Composite